{"product_id":"cummins-rs30-quiet-connect-30kw-standby-generator-120-208v-3-phase","title":"Cummins RS30 Quiet Connect™ 30kW Commercial Standby Generator, 120\/208V 3-Phase","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eIs the Cummins RS30 the Right 30kW Standby Generator for Your Facility?\u003c\/h2\u003e\n\u003cp\u003eThe Cummins RS30 Quiet Connect (part number A051Y402) is a 30kW liquid-cooled standby generator built for \u003cstrong\u003e120\/208V three-phase\u003c\/strong\u003e service. It delivers 104.1 amps at full load, starts and transfers automatically under its PowerCommand 1.1 control, and is capable of meeting NFPA 110 requirements when equipped with the necessary accessories and properly installed. It runs on natural gas or propane vapor, selectable in the field.\u003c\/p\u003e\n\u003cp\u003eIt's sized for businesses that have outgrown a residential home standby but don't need a 100kW-class genset: professional and medical offices, retail, restaurants, churches and small light-commercial buildings on 208V three-phase service. The compact Quiet Connect enclosure measures 94 x 34 x 45.5 inches and weighs 1,231 lb, so it fits sites where larger commercial units won't.\u003c\/p\u003e\n\u003cp\u003eMighty Generators supplies the RS30 by quote. Cummins builds it to order and ships it freight direct, typically in 5 to 6 weeks, so you can have the pad, fuel line and transfer switch ready while it's in production.\u003c\/p\u003e\n\u003ch3\u003eCummins RS30 at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandby rating: 30 kW, 60 Hz\u003c\/li\u003e\n\u003cli\u003eElectrical: 120\/208V three-phase, 104.1 A rated, a 125 A circuit breaker\u003c\/li\u003e\n\u003cli\u003eEngine: Cummins 2.4L turbocharged in-line 4-cylinder, 1800 rpm\u003c\/li\u003e\n\u003cli\u003eFuel: Natural gas or propane vapor, selectable in the field (single fuel, not both at once)\u003c\/li\u003e\n\u003cli\u003eController: Cummins PowerCommand 1.1\u003c\/li\u003e\n\u003cli\u003eSound: 60 dB(A) at 23 ft (7 m) with the optional Sound Level 2 enclosure\u003c\/li\u003e\n\u003cli\u003eSize and weight: 94 x 34 x 45.5 in (L x W x H), 1,231 lb\u003c\/li\u003e\n\u003cli\u003eCode compliance: UL 2200, EPA stationary emergency (40 CFR 60), IBC seismic, NFPA 110 capable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCummins RS30 Features and Performance\u003c\/h2\u003e\n\u003ch3\u003eEngine and Fuel\u003c\/h3\u003e\n\u003cp\u003eThe Cummins 2.4L turbocharged in-line 4-cylinder runs at 1800 rpm with an isochronous electronic governor, so frequency holds steady as loads switch on and off. It's a single-fuel engine that can be set up for natural gas or propane vapor in the field. At full load it uses 380.9 cubic feet per hour of natural gas or 4.5 gallons per hour of propane.\u003c\/p\u003e\n\u003ch3\u003ePowerCommand 1.1 Control\u003c\/h3\u003e\n\u003cp\u003ePowerCommand handles automatic remote starting and stopping, voltage and frequency regulation, alarm and status display, output metering and automatic shutdown when it detects a fault. Voltage regulation is ±1.0% from no load to full load, and random frequency variation is ±0.25% at 60 Hz (ISO 8528-1 Class G3), which matters when the loads include IT equipment, variable-speed drives or medical devices. The flexible exercise mode lets you choose when and how long the generator runs its test cycle, down to as little as 2 minutes every 6 months, which cuts fuel use and noise on site.\u003c\/p\u003e\n\u003ch3\u003eEnclosure and Weather\u003c\/h3\u003e\n\u003cp\u003eThe powder-coated aluminum enclosure comes in Sound Level 1 trim with the muffler installed, in sandstone. Cummins has evaluated it to withstand 180 mph wind loads under ASCE 7-10, and hinged doors open for service. Cummins publishes its sound rating with the optional Sound Level 2 upgrade kit fitted: 60 dB(A) at 23 ft (7 m). If a property line or local noise ordinance is tight, quote the upgrade kit with the generator. Cummins designs the RS30 to start in temperatures as low as -40°F, and the factory coolant heater keeps the engine ready to take load.\u003c\/p\u003e\n\u003ch2\u003eWhere the Cummins RS30 Fits\u003c\/h2\u003e\n\u003cp\u003eStart with the electrical service. This RS30 is wired for 120\/208V three-phase. Cummins builds the RS30 for 120\/240V single-phase and 120\/240V three-phase service too, each under its own part number, so if your building has one of those services, ask us to quote the matching model instead of this one.\u003c\/p\u003e\n\u003cp\u003eTypical applications for a three-phase unit this size:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMedical, dental and veterinary offices that need lights, HVAC, IT and patient equipment through an outage\u003c\/li\u003e\n\u003cli\u003eRetail stores and restaurants protecting refrigeration, point-of-sale and lighting\u003c\/li\u003e\n\u003cli\u003eChurches, community buildings and small offices on 208V three-phase service\u003c\/li\u003e\n\u003cli\u003eTelecom and small server rooms that need regulated, automatic backup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSize the generator from the load, not the square footage. A licensed electrician or engineer should run a load calculation that accounts for motor starting, HVAC and anything on variable-speed drives, and our team can match that number to the right RS model.\u003c\/p\u003e\n\u003ch2\u003eCummins RS30 vs Nearby Quiet Connect Sizes\u003c\/h2\u003e\n\u003cp\u003eIf your calculated load lands close to 30kW, it's worth looking one size either side before you commit. Here's how the RS30 compares with RS25 and RS36 in the same 120\/208V three-phase configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eStandby rating\u003c\/th\u003e\n\u003cth\u003eRated amps (120\/208V)\u003c\/th\u003e\n\u003cth\u003eEngine\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS25\u003c\/td\u003e\n\u003ctd\u003e25 kW\u003c\/td\u003e\n\u003ctd\u003e86.7 A\u003c\/td\u003e\n\u003ctd\u003e2.4L\u003c\/td\u003e\n\u003ctd\u003e1,109 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kW\u003c\/td\u003e\n\u003ctd\u003e104.1 A\u003c\/td\u003e\n\u003ctd\u003e2.4L\u003c\/td\u003e\n\u003ctd\u003e1,231 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS36\u003c\/td\u003e\n\u003ctd\u003e36 kW\u003c\/td\u003e\n\u003ctd\u003e124.9 A\u003c\/td\u003e\n\u003ctd\u003e2.4L\u003c\/td\u003e\n\u003ctd\u003e1,294 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe RS25 to RS40 share a compact enclosure and a 2.4L four-cylinder engine. The RS50 to RS100 move to a 5.9L six-cylinder in a 118.7 inch enclosure, and the RS125 and RS150 use an 8.9L engine in a 143 inch green enclosure with PowerCommand 2.3 control.\u003c\/p\u003e\n\u003ch2\u003ePlanning the Cummins RS30 Installation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransfer switch:\u003c\/strong\u003e sold separately and required. Cummins offers automatic transfer switches in a range of amperages, including service entrance models, all listed to UL 1008.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery and pad:\u003c\/strong\u003e the unit weighs 1,231 lb and ships on a pallet, so plan unloading equipment and a pad sized for its 94 x 34 x 45.5 inch footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElevation and heat:\u003c\/strong\u003e Natural gas: full rated output up to 2,500 ft (762 m) at up to 104°F (40°C); derate 4% per 1,000 ft above that.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories worth quoting:\u003c\/strong\u003e Sound Level 1 to Sound Level 2 enclosure upgrade kit, PowerCommand 500 internet monitoring device, HMI211RS in-home remote display, alternator heater, maintenance and service kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCummins RS30 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eCummins RS30 (A051Y402)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eCummins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eQuiet Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRS30 (C30N6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number (SKU)\u003c\/td\u003e\n\u003ctd\u003eA051Y402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby rating\u003c\/td\u003e\n\u003ctd\u003e30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120\/208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated amps\u003c\/td\u003e\n\u003ctd\u003e104.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine\u003c\/td\u003e\n\u003ctd\u003eCummins 2.4L turbocharged in-line 4-cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated speed\u003c\/td\u003e\n\u003ctd\u003e1800 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane vapor, selectable in the field (single fuel, not both at once)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel consumption\u003c\/td\u003e\n\u003ctd\u003e380.9 ft³\/hr natural gas or 4.5 gal\/hr propane at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003ePowerCommand 1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage regulation\u003c\/td\u003e\n\u003ctd\u003e±1.0%, no load to full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency variation\u003c\/td\u003e\n\u003ctd\u003e±0.25% at 60 Hz (ISO 8528-1 Class G3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound\u003c\/td\u003e\n\u003ctd\u003e60 dB(A) at 23 ft (7 m) with the optional Sound Level 2 enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePowder-coated aluminum, Sound Level 1 with muffler installed, sandstone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWind rating\u003c\/td\u003e\n\u003ctd\u003e180 mph (ASCE 7-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold start\u003c\/td\u003e\n\u003ctd\u003eAs low as -40°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e94 x 34 x 45.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1,231 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude and temperature\u003c\/td\u003e\n\u003ctd\u003eNatural gas: full rated output up to 2,500 ft (762 m) at up to 104°F (40°C); derate 4% per 1,000 ft above that\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCode compliance\u003c\/td\u003e\n\u003ctd\u003eUL 2200; EPA emissions, stationary emergency, 40 CFR 60; IBC seismic; NFPA 110 capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase warranty\u003c\/td\u003e\n\u003ctd\u003e2 years, standby use (Cummins)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandard Equipment on the Cummins Spec Sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCoolant heater\u003c\/li\u003e\n\u003cli\u003eCrankcase vent heater\u003c\/li\u003e\n\u003cli\u003eBattery rack\u003c\/li\u003e\n\u003cli\u003eFlexible fuel line\u003c\/li\u003e\n\u003cli\u003eOperator's manual and installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm the final configuration and any accessories on your written quote.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions About the Cummins RS30\u003c\/h2\u003e\n\u003ch3\u003eWhat electrical service does the Cummins RS30 need?\u003c\/h3\u003e\n\u003cp\u003eThis RS30 (part number A051Y402) is built for 120\/208V three-phase service and is rated 104.1 amps at full load, with a 125 A circuit breaker. Cummins also builds the RS30 for 120\/240V single-phase and 120\/240V three-phase service under different part numbers, so match the generator to your building's service before you order.\u003c\/p\u003e\n\u003ch3\u003eCan the Cummins RS30 run on propane as well as natural gas?\u003c\/h3\u003e\n\u003cp\u003eYes. The RS30 is a single-fuel generator that can be set up for natural gas or propane vapor in the field, though it runs on one fuel at a time, not both. At full load Cummins rates it at 380.9 cubic feet per hour of natural gas or 4.5 gallons per hour of propane, which is what your gas utility or propane supplier will need to size the supply.\u003c\/p\u003e\n\u003ch3\u003eIs the Cummins RS30 suitable for an NFPA 110 emergency power system?\u003c\/h3\u003e\n\u003cp\u003eCummins states the RS30 is capable of meeting NFPA 110 requirements when it's equipped with the necessary accessories and properly installed. It's certified to UL 2200 and EPA stationary emergency emissions rules (40 CFR 60) and meets IBC seismic requirements, and its PowerCommand control supports automatic remote start and shutdown on a detected fault. Your engineer of record or the authority having jurisdiction decides what level your facility needs.\u003c\/p\u003e\n\u003ch3\u003eHow loud is the Cummins RS30?\u003c\/h3\u003e\n\u003cp\u003eWith the optional Sound Level 2 upgrade kit, Cummins rates the RS30 at 60 dB(A) at 23 ft (7 m). The generator ships in a Sound Level 1 aluminum enclosure with the muffler installed, and the Sound Level 2 kit can be added where a property line or noise ordinance calls for it.\u003c\/p\u003e\n\u003ch3\u003eShould I choose the Cummins RS30 or the RS36?\u003c\/h3\u003e\n\u003cp\u003eChoose on calculated load and growth. The RS30 is rated 30kW and 104.1 amps at 120\/208V three-phase; the RS36 is rated 36kW and 124.9 amps and weighs 1,294 lb against 1,231 lb. If your load calculation lands close to 30kW or you expect to add equipment, the RS36 gives you headroom. Send us your load list with a quote request and we'll recommend the size.\u003c\/p\u003e\n\u003ch2\u003eWarranty and Support\u003c\/h2\u003e\n\u003cp\u003eCummins backs the RS30 with a 2-year base warranty when it's used in an EPA stationary emergency (standby) application, and extended Cummins warranties are available. Warranty coverage and service come from Cummins and its certified distributor and dealer network. Mighty Generators is an authorized Cummins dealer: we'll check the configuration against your electrical service, quote the transfer switch and accessories, and coordinate freight to your site.\u003c\/p\u003e\n\u003cp\u003eReady for a quote? Use Request a Quote on this page, or call (888) 775-9048 with your service voltage and a list of the loads you need to carry.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Cummins","offers":[{"title":"120\/208 \/ 3Ph","offer_id":50842193330450,"sku":"A051Y402","price":19172.84,"currency_code":"USD","in_stock":true},{"title":"120\/240 \/ 3Ph","offer_id":50842193363218,"sku":"A051Y405","price":19105.47,"currency_code":"USD","in_stock":true},{"title":"120\/240 \/ 1Ph","offer_id":50842193395986,"sku":"A051Y401","price":19228.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0751\/3885\/9282\/files\/QuietConnectLiquidCooled_25kw-60kw_RS25Front_236b939b-fc6c-4aee-a0c8-33b1ac38fa36.jpg?v=1774390662","url":"https:\/\/mightygenerators.com\/products\/cummins-rs30-quiet-connect-30kw-standby-generator-120-208v-3-phase","provider":"Mighty Generators","version":"1.0","type":"link"}